Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants

The objective of this article is to compare the seismic behavior of two types of energy dissipators applied in a multi-family home: the viscous fluid dissipator and the Shear Link Bozzo (SLB) dissipator. The methodology used is a quantitative and descriptive approach, which allows a detailed structu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Carlos Gabriel Tipula Yanapa, Iziguiel Osias Chocano Roman, Elvis Jhonatan Tamayo Pilco, Néstor Típula Quispe
Formato: Artículo
Lenguaje:inglés
Publicado: 2024
Materias:
Acceso en línea:Enlace permanente (DOI o Handle)
Descargar el archivo
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1881700479781568512
author Carlos Gabriel Tipula Yanapa
Iziguiel Osias Chocano Roman
Elvis Jhonatan Tamayo Pilco
Néstor Típula Quispe
author_browse Carlos Gabriel Tipula Yanapa
Elvis Jhonatan Tamayo Pilco
Iziguiel Osias Chocano Roman
Néstor Típula Quispe
author_facet Carlos Gabriel Tipula Yanapa
Iziguiel Osias Chocano Roman
Elvis Jhonatan Tamayo Pilco
Néstor Típula Quispe
author_sort Carlos Gabriel Tipula Yanapa
collection Producción científica
description The objective of this article is to compare the seismic behavior of two types of energy dissipators applied in a multi-family home: the viscous fluid dissipator and the Shear Link Bozzo (SLB) dissipator. The methodology used is a quantitative and descriptive approach, which allows a detailed structural evaluation of both systems. Two dissipative models are included in the analysis: one traditional, which uses viscous fluid heatsinks, and another contemporary, based on SLB heatsinks. The Tacna accelerometric records were used with an earthquake intensity of 6.2, this for both heatsinks. The results indicate that the viscous fluid dissipator significantly reduces structural drift, with 84.15% in the the structure. For its part, the model with SLB heatsinks achieves an even greater reduction in drift, reaching 91.86% in the X direction and 95.94% in the Y direction, also used in columns and beams. This system demonstrates superior performance in terms of seismic control, providing optimized structural protection. It is concluded that, through a comparative analysis between the 2 modeling, the SLB heatsink presents optimal performance, positioning it as an effective alternative for seismic protection in similar multifamily buildings, contributing to structural safety and social well-being in seismic contexts.
format Article
id openalex:W4405526519
institution UPeU
language English
publishDate 2024
publishDateRange 2024
publishDateSort 2024
record_format dspace
spelling openalex:W4405526519Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy DissignantsCarlos Gabriel Tipula YanapaIziguiel Osias Chocano RomanElvis Jhonatan Tamayo PilcoNéstor Típula Quispeseismic behaviorenergy dissipation devicesviscous dampersmulti-family housingseismic protectionVibration Control and Rheological FluidsSeismic Performance and AnalysisSeismic and Structural Analysis of Tall BuildingsThe objective of this article is to compare the seismic behavior of two types of energy dissipators applied in a multi-family home: the viscous fluid dissipator and the Shear Link Bozzo (SLB) dissipator. The methodology used is a quantitative and descriptive approach, which allows a detailed structural evaluation of both systems. Two dissipative models are included in the analysis: one traditional, which uses viscous fluid heatsinks, and another contemporary, based on SLB heatsinks. The Tacna accelerometric records were used with an earthquake intensity of 6.2, this for both heatsinks. The results indicate that the viscous fluid dissipator significantly reduces structural drift, with 84.15% in the the structure. For its part, the model with SLB heatsinks achieves an even greater reduction in drift, reaching 91.86% in the X direction and 95.94% in the Y direction, also used in columns and beams. This system demonstrates superior performance in terms of seismic control, providing optimized structural protection. It is concluded that, through a comparative analysis between the 2 modeling, the SLB heatsink presents optimal performance, positioning it as an effective alternative for seismic protection in similar multifamily buildings, contributing to structural safety and social well-being in seismic contexts.Articlehttps://doi.org/10.61384/r.c.a..v4i4.697https://estudiosyperspectivas.org/index.php/EstudiosyPerspectivas/article/download/697/1086W4405526519enEstudios y Perspectivas Revista Científica y Académica3005-25992024-12-17
spellingShingle seismic behavior
energy dissipation devices
viscous dampers
multi-family housing
seismic protection
Vibration Control and Rheological Fluids
Seismic Performance and Analysis
Seismic and Structural Analysis of Tall Buildings
Carlos Gabriel Tipula Yanapa
Iziguiel Osias Chocano Roman
Elvis Jhonatan Tamayo Pilco
Néstor Típula Quispe
Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title_full Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title_fullStr Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title_full_unstemmed Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title_short Comparative Analysis of the Seismic Behavior of a Ported Housing applying Energy Dissignants
title_sort comparative analysis of the seismic behavior of a ported housing applying energy dissignants
topic seismic behavior
energy dissipation devices
viscous dampers
multi-family housing
seismic protection
Vibration Control and Rheological Fluids
Seismic Performance and Analysis
Seismic and Structural Analysis of Tall Buildings
topic_facet seismic behavior
energy dissipation devices
viscous dampers
multi-family housing
seismic protection
Vibration Control and Rheological Fluids
Seismic Performance and Analysis
Seismic and Structural Analysis of Tall Buildings
url https://doi.org/10.61384/r.c.a..v4i4.697
https://estudiosyperspectivas.org/index.php/EstudiosyPerspectivas/article/download/697/1086
work_keys_str_mv AT carlosgabrieltipulayanapa comparativeanalysisoftheseismicbehaviorofaportedhousingapplyingenergydissignants
AT iziguielosiaschocanoroman comparativeanalysisoftheseismicbehaviorofaportedhousingapplyingenergydissignants
AT elvisjhonatantamayopilco comparativeanalysisoftheseismicbehaviorofaportedhousingapplyingenergydissignants
AT nestortipulaquispe comparativeanalysisoftheseismicbehaviorofaportedhousingapplyingenergydissignants